PIC PIPE SUPPORT
Contact UsDIMENSIONAL STABILITY
*At – 15°C: Max 1.0% Dimension Change
*At 100°C: Max 1.5% Dimension Change
*At 70°C and 95% RH: Max 2.0% Dimension Change
*All tests are over a 24 hour period: Test to ASTM D2126
DIMENSIONAL TOLERANCE
*Length & Width: ± 2.0 mm maximum
*Thickness: ± 1.0 mm maximum
TECHNICAL SPECIFICATIONS
*Density: Overall density is 77 – 83 kg/m³ | Core sample may exhibit variations of up to 10% Test to SABS 1383 of 1983 – Part 5.6
*Compressive Strength: With drection of rise – 800 kPa. Variations of +10% may be found. Test to SABS 1383 of 1983 – Part 5.7
*Closed Cell Content: Minimum value: 90% Test to SABS 1383 of 1983 – Part 5.8
*Thermal Conductivity: At 10°C: 0.028w/m2°C. Test to SABS 1383 of 1983 – Part 5.9
About us
Shesha Insulation can assist with the materials. The staff capacity and the know how – if you are cornered with a brain picking question. We deliver a friendly and professional services to all our customers that would satisfy even the most pickiest of customers.
We also insulate & clad the following:
– Pipelines – hot, cold, oil, etc.
– Production Lines,
– Ducting,
– Vessels, tanks, burners, etc.
– Exhausts,
– Autoclaves,
– Traced Lines,
– Heat Exchangers,
– Kiln’s
Physical Address
Contact Number
Fax Number
About us
Shesha Insulation can assist with the materials. The staff capacity and the know how – if you are cornered with a brain picking question. We deliver a friendly and professional services to all our customers that would satisfy even the most pickiest of customers.
We also insulate & clad the following:
– Pipelines – hot, cold, oil, etc.
– Production Lines,
– Ducting,
– Vessels, tanks, burners, etc.
– Exhausts,
– Autoclaves,
– Traced Lines,
– Heat Exchangers,
– Kiln’s